3 Channels ECG ECG Holter Monitor
Software Functions & Features:
Apply Demix technology, ensures the accuracy of QRS templates, includes N (Normal), V (Ventricular Ectopy), S (SVE), U (Unknown), P (Pacemaker), A (Artifact). All the templates can be combined or separated as individual beats. beats can be superimposed. Weak signal can be identified such as P wave.
VE, SVE, aberrant beats, V-Tach, V-Pair, V-Bigeminy, Tri-geminy etc.
HRT is the most powerful ECG-related risk predictor for assessing the death risk following myocardial infarction. The predictive value is comparable with that of the LVEF.
Unique pacemaker analysis is suitable for various models i.e. AAI, VVI, DDD, DDR pacemakers.
* HRV (Heart Rate Variability) Analysis
Time domain and Spectral domain HRV analysis, superlower HRV analysis
Heart Rate Variability is analyzed in both Time Domain and Frequency. The top of the HRV display shows the Poincare-Lorenz scatter plots. The lower left shows the Frequency power graph. The range boundaries for LF, LF and HF can be adjusted. The lower right shows the Time Domain histogram. Day and night times can be entered for Sleep Apnea and for A-Fib.
HRT (Heart Rate Turbulence) Analysis
* Atrial Fibrillation and Atrial Flutter Analysis
Atrial Fibrillation is very important for the cardiologist concern. Holter ECG is an excellent test to detect transient A-Fib.
* TWA (T-wave alterans) Analysis
Unknown for the past 40 years, T-Wave Alternans (TWA) in excess of 20 micro-volts have been in Holter recordings but have been undetected. TWA is a strong predictor of V-Tach and other serious cardiac abnormalities. It takes less than 10-seconds to do a complete 24-hour TWA analysis.
You can check for TWA anywhere in teh 24-hour ECG file. Not only can you detect TWA in the ECG file, this software lets you view the ECG showing the actual TWA, so that you can verify and validate the presence of real TWA.
The TWA algorithm detects two modes of TWA. Mode 1 is the beat-to-beat change in T-Wave amplitudes exceeding 20 micro-volts, as shown in the adjacent picture. Mode 2 is the gradual up and down changes of T-wave amplitudes over a series of several beats.
* 12-lead Color LCD Holter recorder
* Compact size, light weight
* Fully programmable, high Fidelity
* Channel: 3 digital recording channels for 12-lead
* Resolution: 12 bit sampling
* Frequency response: 0.05-60Hz
* Recording time: 24 hours, full disclosure, no data compression, 3 channel ECG
* Storage: 2G built-in flash memory
* LCD display: ECG waveform and lead number
* Weight: 75 grams (battery not included)
* Lead: 7 wire patient cable
1. Holter software CD with dongle key: 1 set
2. 3-channel Holter recorder: 1 unit
3. 5-lead Holter lead wire: 1 set