Kohler 200A se transfer sw intelligent 1PH 40SP sqd qo


Intelligent Transfer Switch Model: RSB
Service Entrance Rated Load Center with Generator Control and Load Transfer Mechanism for Kohler Generators
Automatic Transfer Switch Standard Features:
Complete unit includes load transfer mechanism, microprocessor controller, wiring harnesses, load center,* and enclosure
UL 67 listed and tested to UL 1008
Service entrance rated automatic transfer switch with prewired
Suitable for service entrance or sub-panel use
Compatible with all Kohler 8.5-30RES generator sets
Two-pole, single-phase open-transition transfer switch
Transfer mechanism electrically and mechanically interlocked
Transfer mechanism manually operable for maintenance purposes
Type 1, for indoor installation, up to 40 circuits;* can be installed flush to the wall or on the surface
G11-101 (Model RSB Automatic Transfer Switch)
Operating temperature -10C to 40C (-140F to 104F) without derating -10C to 60C (-140F to 140F) with derating Storage temperature -40C to 75C (-40F to 167F)
Humidity 5 to 95% noncondensing
Engine start 0.5 A @ 125 VAC; 2 A @ 30 VDC SPST normally closed (NC) Load control 10 A @ 120 VAC SPST normally open (NO)
Connection Range of Wire Sizes, Cu/Al
Normal Source, 150-225 A #4 AWG to 300 kcmil
Emergency Source #14 to 2/0 AWG
Enclosure Number of Circuits 40 Weight, kg (lb.) 25 Dimensions, H x W x D, mm (in.) (39.4 x 14.25 x 3.75)
Main and Generator Circuit Breaker Ratings
Main circuit breaker Type QOM2 VH 200 QOM2- Generator breaker 80
Main and generator source circuit breakers are included with the transfer switch. Branch circuit breakers are not included. Obtain
type QObranch circuit breakers locally as required.
Factory Adjustment with Accessory Board Time Delay
Engine Start 3 sec. 1-10 sec. 1 second
Transfer from Normal to Emergency 3 sec. 1-10 sec. 1 second
Retransfer from Emergency to Normal 6 min. 3-30 min. 3 minutes
Engine Cooldown 5 min. 1-10 min. 1 minute
Exercise Run Time 20 min. 5-50 min. 5 minutes
Exercise Interval 1 week 1 week/2 week (DIP switch)
Failure to Acquire Emergency Source 78 sec. NA
Undervoltage Dropout 0.5 sec. NA
Underfrequency Dropout 1 sec. NA
Accessory board is required for time delay adjustments.
Maximum continuous loads not to exceed 80% of the ampere rating of any overcurrent device installed.
RMS Symmetrical Amperes at 240 VAC, Max.
Catalog Designation or Fuse Class (Max. A) *
Branch Circuit Breaker Catalog Description (Max. A)
10,000 QO(125) Emergency (Generator)
QO(125) and QOT 22,000 QOM-VH(200) Normal (Utility) QO(125) and QOT
* See circuit breaker for voltage and interrupting rating. The rating is equal to the lowest interrupting rating of any circuit breaker installed. Refer
to branch or main circuit breakers for individual ratings. Additional or replacement branch or main circuit breaker or service disconnect MUST
have an interrupting rating equal to or greater than that of the circuit breaker with the lowest interrupting rating presently installed.
QO includes QO-GFI, QO-EPD, and QO-AFI.
Certifications, Codes and Standards
The ATS meets or exceeds the requirements of the following
UL listed under Underwriters Laboratories UL 67, Enclosed Panel Boards
Tested to Underwriters Laboratories UL 1008, Standard for
Automatic Transfer Switches for Use in Optional Standby Systems
NFPA 70, National Electrical Code, Article 702
NEMA Standard IC10-1993, AC Automatic Transfer Switches
IEC 61000-4-2, 2001: ESD Electrostatic Discharge, Level 3
IEC 61000-4-3, 2002: Radiated Immunity, Level 2
IEC 61000-4-4, 2001: EFT/Burst Immunity, Severity Level 3
IEC 61000-4-5, 2001: Surge Immunity, Severity Level 4
IEC 61000-4-6, 2003: Conducted RF Immunity, Level 2
FCC Part 15, Radiated Emissions, Class B
FCC Part 15 Using CISPR 11 Conducted Emissions, Class B
Alarm horn indicates system faults
Remote start/stop input (loaded)
Generator set supplying load output:
10 A @ 120 V SPST normally open (NO) contact
Momentary/maintained external start/stop input:
Selects momentary (1 second) push button or
maintained contact closure for remote start/stop signal
Literature is provided with every unit Additional literature kits are available Specifications pdfSell Sheet.pdf