Lot of test equipment 40PCS hp tektronix lambda fluke
1. HP 183A Oscilloscope with 1830A/1840A- Display screen is ok. Unit will not measure input signals. Sweep time/SIN knob is stuck and will not move.
2. HP 1804A Oscilloscope-ALl four channel functions don't work. No display. Storage surface is intermittent.
3. Logimetrics 750A RF Signal Generator-No RF signal Output at 50 ohms at any hi/lo frequencies.
4. Nicolet 204 Storage Oscilloscope-Display is very intermittent. Will not go to normal.
5. HP 3575A Gain Phase Meter-Amplitude B Phase switch is broken. Can not get an accurate readings on this unit. Mechanical problems.
6. HP 1200B Oscilloscope-100 UV dual trace horizontal sweep control is drifting and fading.
7. HP 1200B Oscilloscope-Unit powers up, signals are ok on CH A & B. Connector on end of the high voltage scope tube is broken causing the tube to be loose. Internal damage.
8. HP 6255A Dual DC Power Supply-Channel B is internally shorted, effecting CH A when unit is powered up.
9. Singer/Empire TX/NF-105 Tuning Unit- no power. no signal output.
10. Power Mate BP-34D Regulated Power Supply-Voltage adjust works. Power supply is making a loud hum. Transformer going bad.
11. HP 209 A Oscillator-All functions fail test. No signal output on all ranges. Large knob hard to adjust mechanically.
12. HP 5316B Universal Counter-Intermittent display. Counter does not measure frequency at a good level.
13. HP 5316B Universal Counter-Channel A frequency ranges are out of limits. Other functions are OK.
14. Analog Digital Research CM52 Counter Timer-Display missing one LED segment. Will not read any numbers on display.
15. Lambda LP412A FM Regulated Power Supply-Current limiter is intermittent causing high voltage output. Internal problems.
16. Lambda LP412A FM Regulated Power Supply-No voltage output. Unit is non workable.
17. Lambda LP411A-FM Regulated Power Supply-Current is limited up to 15 volts, too high. Unit is very limited in its use.
18. Lambda LP411A FM Regulated Power Supply-Unit is working but has some chips on the face plate.
19. Fluke 8050A Digital Multimeter-AC voltage ranges do not work. All other funtions work. Partial init works.
20. Fluke 8050A Digital Multimeter-Resistor ranges are intermitten out of limits. All other funtions work. Partial unit works.
21. HP 4288 Milliammeter-Unit powers up. Can't test due to missing probe.
22. HP 4288 Milliammeter-Unit powers up. Can't test due to missing probe.
23. Logimetrics 750A RF Signal Generator-No signal output.
24. Simpson 270 Milliammeter-Missing batteries. One end of a diode is broken loose form the insise board. Casing is broken.
25. Simpson 260 Series 7 Milliammeter-All functions failed.
26. Simpson 260 Series 3-Nonworking
27. Lamda LPD 421 FM Dual Regulated Power Supply- Channel A is dead, Channel B is working.
28. HP 5315B Universal Counter-The frequency display reloads itself from 0-9 MHZ in a cycle. Unit will not measure frequencies. Internal problem.
29.Heathkit IP 2718 Tri Power Supply-Meter knob is stuck, hard to move. Channel A, B has not output voltages. Meter knob problems inside.
30. Lambda LP 533 FM-Output voltage intermittent. Adjust, then it drops to 0 volts. Current limiter is low. Internal problems.
31. Dranetz Sampling Log Voltmeter Series 220-Partial function work. High Pass in KHZ; .1 range does not work. Sampling time in MS; .1 range does not work.
32.Tektronix Type 130 LC Meter-The meter facce needle gets stuck in the middle when testing a component. Non-functional. Also it is cracked & broken.
33. lambda LPD 421A FM Dual Regulated Power Supply-CH A, CH B does not work.
34.Klinger Scientific Micro Control-Untested
35. Lambda LP 522 FM-Voltage adjust does not work. No output.
36. Lambda LP 522 FM- Voltage Adjust out is intermittent.
37. Lambda LPD 421A-FM Dual Regulated Power Supply-CH A works. CH B voltage adjust is intermittent. Internal problem.
38. HP 331A Distortion Analyzer-Frequency Range X100-all ranges have no signal output. Internal problems.
39. HP331A Distortion Analyzer-Frequency Range X100-all ranges are stuck on 55.7KHZ, will not adjust. Unit does power up.
40. LambdaLP 412 FM-Basic voltage ranges work. A working unit.