Lot of test equipment 40PCS hp tektronix lambda fluke


1. HP 183A Oscilloscope with 1830A/1840A- Display screen is ok. Unit will not measure input signals. Sweep time/SIN knob is stuck and will not move.
2. HP 1804A Oscilloscope-ALl four channel functions don't work. No display. Storage surface is intermittent.
3. Logimetrics 750A RF Signal Generator-No RF signal Output at 50 ohms at any hi/lo frequencies.
4. Nicolet 204 Storage Oscilloscope-Display is very intermittent. Will not go to normal.
5. HP 3575A Gain Phase Meter-Amplitude B Phase switch is broken. Can not get an accurate readings on this unit. Mechanical problems.
6. HP 1200B Oscilloscope-100 UV dual trace horizontal sweep control is drifting and fading.
7. HP 1200B Oscilloscope-Unit powers up, signals are ok on CH A & B. Connector on end of the high voltage scope tube is broken causing the tube to be loose. Internal damage.
8. HP 6255A Dual DC Power Supply-Channel B is internally shorted, effecting CH A when unit is powered up.
9. Singer/Empire TX/NF-105 Tuning Unit- no power. no signal output.
10. Power Mate BP-34D Regulated Power Supply-Voltage adjust works. Power supply is making a loud hum. Transformer going bad.
11. HP 209 A Oscillator-All functions fail test. No signal output on all ranges. Large knob hard to adjust mechanically.
12. HP 5316B Universal Counter-Intermittent display. Counter does not measure frequency at a good level.
13. HP 5316B Universal Counter-Channel A frequency ranges are out of limits. Other functions are OK.
14. Analog Digital Research CM52 Counter Timer-Display missing one LED segment. Will not read any numbers on display.
15. Lambda LP412A FM Regulated Power Supply-Current limiter is intermittent causing high voltage output. Internal problems.
16. Lambda LP412A FM Regulated Power Supply-No voltage output. Unit is non workable.
17. Lambda LP411A-FM Regulated Power Supply-Current is limited up to 15 volts, too high. Unit is very limited in its use.
18. Lambda LP411A FM Regulated Power Supply-Unit is working but has some chips on the face plate.
19. Fluke 8050A Digital Multimeter-AC voltage ranges do not work. All other funtions work. Partial init works.
20. Fluke 8050A Digital Multimeter-Resistor ranges are intermitten out of limits. All other funtions work. Partial unit works.
21. HP 4288 Milliammeter-Unit powers up. Can't test due to missing probe.
22. HP 4288 Milliammeter-Unit powers up. Can't test due to missing probe.
23. Logimetrics 750A RF Signal Generator-No signal output.
24. Simpson 270 Milliammeter-Missing batteries. One end of a diode is broken loose form the insise board. Casing is broken.
25. Simpson 260 Series 7 Milliammeter-All functions failed.
26. Simpson 260 Series 3-Nonworking
27. Lamda LPD 421 FM Dual Regulated Power Supply- Channel A is dead, Channel B is working.
28. HP 5315B Universal Counter-The frequency display reloads itself from 0-9 MHZ in a cycle. Unit will not measure frequencies. Internal problem.
29.Heathkit IP 2718 Tri Power Supply-Meter knob is stuck, hard to move. Channel A, B has not output voltages. Meter knob problems inside.
30. Lambda LP 533 FM-Output voltage intermittent. Adjust, then it drops to 0 volts. Current limiter is low. Internal problems.
31. Dranetz Sampling Log Voltmeter Series 220-Partial function work. High Pass in KHZ; .1 range does not work. Sampling time in MS; .1 range does not work.
32.Tektronix Type 130 LC Meter-The meter facce needle gets stuck in the middle when testing a component. Non-functional. Also it is cracked & broken.
33. lambda LPD 421A FM Dual Regulated Power Supply-CH A, CH B does not work.
34.Klinger Scientific Micro Control-Untested
35. Lambda LP 522 FM-Voltage adjust does not work. No output.
36. Lambda LP 522 FM- Voltage Adjust out is intermittent.
37. Lambda LPD 421A-FM Dual Regulated Power Supply-CH A works. CH B voltage adjust is intermittent. Internal problem.
38. HP 331A Distortion Analyzer-Frequency Range X100-all ranges have no signal output. Internal problems.
39. HP331A Distortion Analyzer-Frequency Range X100-all ranges are stuck on 55.7KHZ, will not adjust. Unit does power up.
40. LambdaLP 412 FM-Basic voltage ranges work. A working unit.



Lot of test equipment 40PCS hp tektronix lambda fluke Lot of test equipment 40PCS hp tektronix lambda fluke Lot of test equipment 40PCS hp tektronix lambda fluke Lot of test equipment 40PCS hp tektronix lambda fluke Lot of test equipment 40PCS hp tektronix lambda fluke Lot of test equipment 40PCS hp tektronix lambda fluke Lot of test equipment 40PCS hp tektronix lambda fluke Lot of test equipment 40PCS hp tektronix lambda fluke